Inscreed Heating Cable
Inscreed heating cable is designed for installation in concrete screed, and is ideal for new-build projects where floor height is not an issue. The Inscreed cable is suitable for almost any flooring finish. With slower heat-up and cool-down speed, the inscreed cable heating system is suitable for rooms which are in constant use. In addition, the screed can be used as a form of heat storage and result in cost savings by making use of discounted electricity rates during non-peak hours.
-
Features
-
Specification
Cable construction: Twin cores with one solid Nickel Copper Alloy heating conductor
and one solid copper return wire
Insulation: XLPE
Screen: 100% with Aluminum foil + Tinned-Copper wire
Outer sheath: PVC
Cable diameter: 7 mm
Apply Voltage: 230V
Linear Output: 17W/m
Cold Tail Length: 3mModels Available
Cable Length and Power Model Number Cable Length(M) Total Power(Wattage) Total Current(Amp) Resistance(Ohm) UTC017ME3-0100 10 170 0.7 311.2 UTC017ME3-0150 15 254 1.1 208.3 UTC017ME3-0210 21 360 1.6 146.9 UTC017ME3-0270 27 460 2 115 UTC017ME3-0350 35 600 2.6 88.2 UTC017ME3-0410 41 700 3 75.6 UTC017ME3-0540 54 900 3.9 58.8 UTC017ME3-0650 65 1100 4.8 48.1 UTC017ME3-0790 79 1340 5.8 39.5 UTC017ME3-0840 84 1450 6.3 36.5 UTC017ME3-0960 96 1650 7.2 32.1 UTC017ME3-1120 112 1900 8.3 27.8 UTC017ME3-1410 141 2400 10.4 22 UTC017ME3-1700 170 2900 12.6 18.2 UTC017ME3-1830 183 3100 13.5 17.1 -
Specification
Cable construction: Twin-core solid Nickel Copper Alloy heating conductors
Insulation1: FEP
Insulation2: XLPE
Screen: 100% Tinned-Cu braid
Outer sheath: PVC
Cable diameter: 7 mm
Apply Voltage: 230V
Linear Output: 17W/m
Cold Tail Length: 3mModels Available
Cable Length and Power Model Number Cable Length(M) Total Power(Wattage) Total Current(Amp) Resistance(Ohm) UTB017ME3-0100 10 170 0.7 311.2 UTB017ME3-0150 15 254 1.1 208.3 UTB017ME3-0210 21 360 1.6 146.9 UTB017ME3-0270 27 460 2 115 UTB017ME3-0350 35 600 2.6 88.2 UTB017ME3-0410 41 700 3 75.6 UTB017ME3-0540 54 900 3.9 58.8 UTB017ME3-0650 65 1100 4.8 48.1 UTB017ME3-0790 79 1340 5.8 39.5 UTB017ME3-0840 84 1450 6.3 36.5 UTB017ME3-0960 96 1650 7.2 32.1 UTB017ME3-1120 112 1900 8.3 27.8 UTB017ME3-1410 141 2400 10.4 22 UTB017ME3-1700 170 2900 12.6 18.2 UTB017ME3-1830 183 3100 13.5 17.1
-
-
Features
- Free form cable allows for full coverage of any room especially those with curves and angles
- Flexible cable to cable spacing for easy adjusting the power outputs per square feet
- Floor coverings can be changed without damaging the cables
- Suitable for any floor coverings.
- Safe and durable
Specification
Cable construction: Twin cores with one solid Nickel Copper Alloy heating conductor + one solid copper return wire
Insulated with XLPE
Cable diameter 0.3 inch (7 mm)
Apply Voltage: 120V and 240V
Linear Output: 5W/FT
Outer sheath: PVC
Screen: 100% with Aluminum foil + Tinned-Copper wire
Cold Tail Length: 9.8ft (3m)-
Cable Length and Power Model Number Cable Length(FT) Total Power(Wattage) Total Current(Amp) Resistance(Ohm) UTC005FT1-0058 58 300 2.5 48 UTC005FT1-0077 77 400 3.3 36 UTC005FT1-0097 97 500 4.2 28.8 UTC005FT1-0116 116 600 5 24 UTC005FT1-0135 135 700 5.8 20.6 UTC005FT1-0162 162 840 7 17.1 -
Cable Length and Power Model Number Cable Length(FT) Total Power(Wattage) Total Current(Amp) Resistance(Ohm) UTC005FT4-0058 58 300 1.3 192 UTC005FT4-0077 77 400 1.7 144 UTC005FT4-0097 97 500 2.1 115.2 UTC005FT4-0116 116 600 2.5 96 UTC005FT4-0135 135 700 2.9 82.3 UTC005FT4-0162 162 840 3.5 68.6 UTC005FT4-0193 193 1000 4.2 57.6 UTC005FT4-0241 241 1250 5.2 46.1 UTC005FT4-0260 260 1350 5.6 42.7 UTC005FT4-0328 328 1700 7.1 33.9